Cold aisle solution

We analyse your infrastructure on-site and design your individual cold aisle solution. On request, we document it on the basis of energy and temperature measurements. Using these, we produce a detailed forecast of the potential energy saving or the optimised temperature distribution. The savings can be demonstrated by a second measurement.

bit – a solution that fits

The cold aisle solution from bit for your (existing) computer centre:

  • …is individually planned
  • …fits every rack format
  • …covers any aisle widths
  • …can be expanded at any time
  • …always fits

 

Illustration

Description

Article no.

files/img/Kaltgangeinhausung/Grundkonstruktion.jpg

Basic structure

The basic structure consists of individually sawn-to-length aluminium extruded profiles. It can be installed suspended from the roof or on supports. The racks can thus be replaced at any time without altering the basic structure. Pre-existing building features such as pillars, supports, binding beams or other obstacles are integrated into the structure.

10.00

files/img/Kaltgangeinhausung/Dachmodule_normal.JPG

Roof modules

Individually adjusted roof modules. Openings for fire extinguishing nozzles, existing cabling or other requirements are worked in individually.

Consisting of:

  • profile structure (see article 10.00.)
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent
  • alternatively also with laminated glass

 

10.10

files/img/Kaltgangeinhausung/Dachmodule.JPG

Roof modules with ridge

Self-supporting structure that can be attached to the floor, walls or ceiling. Openings for fire extinguishing nozzles, existing cabling or other requirements are incorporated individually. Consisting of:

  • profile structure (see article 10.00.)
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent
  • alternatively also with laminated glass

 

10.20

files/img/Kaltgangeinhausung/Klapptuere_komplett_2310.JPG

Folding doors

Door including frame. Consisting of:

  • profile structure (see article 10.00.)
  • off-set handle
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent
  • Design freely selectable:
    • hinge side (left or right)
    • two-leaved
    • self-closing

 

 

 

 

 

 

10.30.0
10.31.0
10.xx.1

files/img/Kaltgangeinhausung/Schiebetuer_komplett_2310.JPG

Sliding doors

Door including frame. Consisting of:

  • profile structure (see article 10.00.)
  • off-set handle
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent
  • Design freely selectable:
    • mounting side (left or right)
    • self-closing

 

 

 

 

 

 

10.40.0
10.40.1

files/img/Kaltgangeinhausung/Spacer_klein_600x290.JPG

Rack leveler with profile frame

Individual rack-leveler for sealing empty spaces between the roof modules and racks. Elements can be removed at any time and adapted to altered rack dimensions. Consisting of:

  • profile structure (see article 10.00.)
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent

 

10.50

files/img/Kaltgangeinhausung/PVC_Platte_710x180x4.JPG

Rack leveller without profile frame

Individual rack leveller for sealing empty spaces between the roof modules and racks. Elements can be removed at any time and adapted to altered rack dimensions. Consisting of:

  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent

 

10.60

files/img/Kaltgangeinhausung/Spacer_800x2310.JPG

Rack spacer

Individual rack spacer made of aluminium profiles for filling unused empty spaces for future racks. Consisting of:

  • profile structure (see article 10.00.)
  • Makrolon in B1 (flame-resistant); material thickness in 4 mm, transparent

 

10.70.

 

Saving at a high level

Lowering energy costs for cooling is the order of the day. Talk to bit, because we will not just design and install your cold aisle containment, but also adapt the air conditioning regulation:

  • adjustment of the air quantity
  • increasing inlet air temperature
  • increasing cold water temperature
  • energy controlling to prove success of the measure

 

Cold aisle containment on its own is no solution:

bit offers additional services:

  • double floors – sealing, adjusting, optimising
  • cable entries - optimisation
  • rack sealing – with panels, brushes and plastic foam
  • air conditioning control – adjusted precisely to requirements
  • energy controlling – measure, manage, regulate and integrate in the building management service
  • Maintenance – ensuring that everything functions

 

Challenge us. Simply send a floor plan or sketch of the rack rows (including dimensions) to be contained to office@bit-germany.de.

We would be pleased to make you a non-binding offer.